Overview

With 5mm long sensor, AM1610 series precision industrial PRT provides users an excellence temperature probe with extremely low stem conduction (heat loss along sheath) in precision temperature measurement. It is a great tool for measuring and testing the vertical temperature uniformity of heat sources. 

AM1610 uses a special aged and tested 5-mm long sensing element to achieve the best performance in stability and repeatability. A unique assembly procedure provides the best balance among the hysteresis effect, mechanical shock and thermal shock performance. 
Features
·    Temperature range: -60 °C to 160 °C
·    Sensor Length: 5 mm
·    Accuracy: ±0.05 °C
·    Long term drift: ±0.04 °C
·    Short term stability: 0.01 °C
·    Durable and shock resistance
·    Temperature Coefficient 0.00385
·    SST sheath
·    Quick response time
·    Customized dimensions available
Specifications
 
Temperature Range
-60°C to 160°C
Resistance at 0 °C
Nominal 100 Ω
Temperature Coefficient
0.00385 Ω/ Ω/°C
Accuracy
±0.05°C
Drift
±0.04°C at 0 °C after 100 hours at 160 °C
Short Term Stability
±0.01°C
Thermal Shock
±0.01°C after 10 times thermal cycles from minimum to maximum temperatures
Hysteresis
Self-heating
75 mW/°C
Response Time
4 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current
0.5 mA or 1 mA
Sensor Length
5 mm
Sensor Location
3 mm from tip
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
Stainless Steel 316L
Dimension
1610-12: 0.25 inch X 12 inch (6.35 mm X 305 mm)
1610-9:  0.187 inch X 9 inch (4.75 mm X 229 mm)
External Leads
Teflontm –insulated copper wire, 4 leads, 2.5 meters
Handle Dimension
1610-12: 15mm (OD) X 65 mm (L)
1610-9: 10mm (OD) X 50 mm (L)
Handle Temperature Range*
-30°C to 150°C
Calibration Options
1610-12-T, PRT with NIST traceable calibration and data
1610-9-T, PRT with NIST traceable calibration and data
   *Handle temperature outside this range will cause damage to the probe.
Optional Accessories
Model
Description
9001
Carrying Case

 

 

Overview

AM1612 full immersion PRT is uniquely designed to provide users an excellence temperature probe that can expose the transition junction and lead wires to an environment that covers the full PRT temperature range. The seal of probe prevents the ingress of moisture so that the probe can work in a humid condition or even under full immersion in common heat transfer fluids such as ethanol, silicone oil and mineral oil.  

AM1612 is small in size with probe length of 50 mm and diameter of 3 mm. A unique assembly procedure provides the best balance among the hysteresis effect, mechanical shock and thermal shock performance

Features

·    Temperature range: -196 °C to 180 °C

·    Probe Length: 50 mm

·    Accuracy: ±0.05 °C at 0 °C

·    Long term drift: ±0.04 °C

·    Short term stability: 0.02 °C

·    Durable and shock resistance

·    Temperature Coefficient 0.00385

·    SST sheath
Specifications
 
Temperature Range
-196°C to 180°C
Resistance at 0 °C
Nominal 100 Ω
Temperature Coefficient
0.00385 Ω/ Ω/°C
Accuracy
±0.05°C at 0 °C
Drift
±0.04°C at 0 °C after 100 hours at 160 °C
Short Term Stability
±0.02°C
Thermal Shock
±0.02°C after 10 times thermal cycles from minimum to maximum temperatures
Hysteresis
Self-heating
75 mW/°C
Response Time
4 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current
1 mA
Sensor Length
30 mm
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
Stainless Steel 316L
Dimension
0.125 inch X 2 inch (3 mm X 50 mm)
External Leads
Enameled copper wire protected by high temperature heat shrink tubing, 4 leads, 2.5 meters
Calibration Options
1612-T, PRT with NIST traceable calibration and data

Optional Accessories

Model
Description
9001
Wooden Carrying Case

 

Overview

AM1642 full immersion PRT features a unique design that allows for the users to apply the probe together with its lead wire in a high temperature environment such as ovens or furnaces etc. It covers a wide range of temperature from 0 °C to 420 °C with amazing accuracy of ±0.04°C at 0 °C, short term stability of ±0.02°C and fast respond time of 5 seconds. The standard length is 4-inch but customized dimensions are available per request. Customized length can range from 2 inches to 12 inches.   

To reach the best performance in stability and repeatability, the wire-wound sensing elements are specially designed to protect the platinum sensing wire from contamination at high temperature. A unique support structure and filling material provide the best balance among the hysteresis effect, mechanical shocks and thermal shock performance. This probe conforms to the DIN/IEC-751 curve precisely
Features
·    Temperature range: 0 °C to 420 °C
·    Accuracy: ±0.04 °C at 0 °C
·    Long term drift: ±0.04 °C
·    Short term stability: 0.02 °C
·    Transition junction and lead wire can withstand the full temperature range of the PRT
·    Temperature Coefficient 0.00385
·    Follow DIN/IEC-751 precisely
·    Inconeltm sheath
·    Quick response time
·    Customized dimensions available
Specifications
 
Temperature Range
0°C to 420°C                                      
Resistance at 0 °C
Nominal 100 Ω
Temperature Coefficient
0.00385 Ω/ Ω/°C
Accuracy*
±0.04°C at 0°C
±0.05°C at 200°C
±0.07°C at 420°C
Drift
±0.04°C at 0 °C after 100 hours at 420 °C
Short Term Stability
±0.02°C
Thermal Shock
±0.02°C after 10 times thermal cycles from minimum to maximum temperatures
Hysteresis
Self-heating
50 mW/°C
Response Time
5 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current
1 mA
Minimum immersion depth
50 mm
Maximum immersion depth
Dry medium: full immersion
Liquid medium: use protective tube if immersion depth reaches transition junction
Sensor Length
30 mm
Insulation Resistance
>500 MΩ at room temperature
Sheath Material
Inconeltm
Dimension
0.125 inch X 4 inch (3 mm X 100 mm)
(length of the probes can be customized per request, range from 2 inches to 12 inches)
External Leads
Four fiberglass insulation Ni-plated copper wires, 2.5 meters (longer lead wires are available per request)
Handle Dimension
6.4 mm (OD) X 25 mm (L)
             *With optional calibration.

Optional Accessories
 
Model
Description
9001
Wooden Carrying Case


 

Overview

AM1620/1640/1660 series precision industrial PRTs are top choices when price-to-performance is considered. They cover a wide range of temperature from -200 °C to 670 °C with amazing accuracy of ±0.035°C at 0 °C, short term stability of ±0.01°C and fast respond time of 5 seconds. These industrial PRTs come with standard length 12-inch but customized dimensions are available per request.   

To reach the best performance in stability and repeatability, the wire-wound sensing elements are specially designed to protect the platinum sensing wire from contamination at high temperature. A unique support structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. All of these probes conform to the standard 385 curve so the resistance ratio of the PRT follow DIN/IEC-751 curve precisely.
Features
·    Temperature range: -200 °C to 670 °C
·    Accuracy: ±0.035 °C at 0 °C
·    Long term drift: ±0.04 °C
·    Short term stability: 0.01 °C
·    Durable and shock resistance
·    Temperature Coefficient 0.00385
·    Follow DIN/IEC-751 precisely
·    Inconeltm sheath
·    Quick response time
·    Customized dimensions available

Specifications

Temperature Range
1660: -200°C to 670°C                       
1640: -200°C to 420°C                       
1620: -60°C to 300°C
Resistance at 0 °C
Nominal 100 Ω
Temperature Coefficient
0.00385 Ω/ Ω/°C
Accuracy
±0.04°C at -200°C
±0.035°C at 0°C
±0.05°C at 200°C
±0.09°C at 420°C
±0.15°C at 660°C
Drift
±0.04°C at 0 °C after 100 hours at 420 °C
Short Term Stability
±0.01°C
Thermal Shock
±0.007°C after 10 times thermal cycles from minimum to maximum temperatures
Hysteresis
Self-heating
50 mW/°C
Response Time
5 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current
0.5 mA or 1 mA
Sensor Length
32 mm
Sensor Location
5 mm from tip
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
1660/1640: Inconeltm
1620: 316 Stainless Steel
Dimension
0.25 inch X 12 inch (6.35 mm X 305 mm)
External Leads
Teflontm –insulated copper wire, 4 leads, 2.5 meters
Handle Dimension
15mm (OD) X 65 mm (L)
Handle Temperature Range*
-50°C to 180°C
Calibration Options
1660-12-T, PRT with NIST traceable calibration and data
1640-12-T, PRT with NIST traceable calibration and data
1620-12-T, PRT with NIST traceable calibration and data
NVLAP - Accredited Calibrations available per request

  *Handle temperature outside this range will cause damage to the probe.

Optional Accessories

Model
Description
9001
Carrying Case

 

Overview

AM1730 series Secondary Reference PRT provides our customers an affordable reference probe for precision temperature measurement and calibration in labs and fields. The PRT features accuracy of ±0.015°C, short term stability of ±0.007°C.  Two different lengths of PRTs are available at 9-inch and 12-inch.   

To reach the best performance in stability and repeatability, the sensing element is specially designed to protect the platinum sensing wire from contamination at high temperature. A unique support structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe meets ITS-90 criteria of reference thermometer fully.
Features
·    Temperature range: -200 °C to 420 °C
·    Accuracy: ±0.015 °C
·    Long term drift: ±0.01 °C
·    Short term stability: 0.007 °C
·    Durable and shock resistance
·    Temperature Coefficient 0.003925
·    W(Ga)>=1.11807
·    Inconeltm sheath
·    Customized dimensions available
Specifications
 
Temperature Range
1730-12: -200°C to 420°C
1730-9: -60°C to 300°C
Resistance at 0 °C
Nominal 100 Ω
Temperature Coefficient
0.003925 Ω/ Ω/°C
Accuracy
±0.025°C at -196 °C
±0.015°C at 0.01 °C
±0.035°C at 420 °C
Drift
±0.01°C at 0 °C after 100 hours at 420 °C
Short Term Stability
±0.007°C
Thermal Shock
±0.005°C after 10 times thermal cycles from minimum to maximum temperatures
Hysteresis
Self-heating
50 mW/°C
Response Time
9 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current
0.5 mA or 1 mA
Sensor Length
32 mm
Sensor Location
5 mm from tip
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
Inconeltm
Dimension
 1730-12: 0.25 inch X 12 inch (6.35 mm X 309 mm)
1730-9: 0.187 inch X 9 inch (4.75 mm X 229 mm)
External Leads
Teflontm –insulated copper wire, 4 leads, 2.5 meters
Handle Dimension
1730-12: 15mm (OD) x 65mm (L)
1730-9: 10mm (OD) X 50 mm (L)
Handle Temperature Range*
-50°C to 180°C
Calibration Options
1730-12-T, PRT with NIST traceable calibration and data
1730-9-T, PRT with NIST traceable calibration and data
NVLAP - Accredited Calibrations available per request
   *Handle temperature outside this range will cause damage to the probe.
Optional Accessories
Model
Description
9001
Carrying Case

 

 

Overview

AM1750 series Secondary Reference PRT provides our customers an affordable reference probe for precision temperature measurement and calibration in labs and fields. The PRT features accuracy of ±0.015°C at 0.01°C ; short term stability of ±0.007°C.  Two different lengths of PRTs are available at 12-inch and 20-inch.   

The sensing element is designed to protect the platinum sensing wire from contamination at high temperatures, giving the device a high level of stability and repeatability in performance. A uniquely designed support structure and filling material provides excellent balance between the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe fully meets ITS-90 criteria for reference thermometers.

Features

·    Temperature range: -200 °C to 670 °C

·    Accuracy: ±0.015 °C at 0.01°C

·    Long term drift: ±0.01 °C

·    Short term stability: 0.007 °C

·    Durable and shock resistance

·    Temperature Coefficient 0.003925

·    W(Ga)>=1.11807

·    Inconeltm sheath

·    Customized dimensions available
Specifications
 
Temperature Range
1750-12: -200°C to 670°C
1750-20: -200°C to 670°C
Resistance at 0 °C
Nominal 100 Ω
Temperature Coefficient
0.003925 Ω/ Ω/°C
Accuracy
±0.025°C at -196 °C
±0.015°C at 0.01 °C
±0.035°C at 420 °C
±0.05°C at 660 °C
Drift
±0.01°C at 0 °C after 100 hours at 660 °C
Short Term Stability
±0.007°C
Thermal Shock
±0.005°C after 10 times thermal cycles from minimum to maximum temperatures
Hysteresis
Self-heating
50 mW/°C
Response Time
9 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current
0.5 mA or 1 mA
Sensor Length
32 mm
Sensor Location
5 mm from tip
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
Inconeltm
Dimension
1750-12: 0.25 inch X 12 inch (6.35 mm X 305 mm)
1750-20: 0.25inch X 20 inch (6.35 mm X 500 mm)
External Leads
Teflontm –insulated copper wire, 4 leads, 2.5 meters
Handle Dimension
15mm (OD) X 65 mm (L)
Handle Temperature Range*
-50°C to 180°C
Calibration Options
1750-12-T, PRT with NIST traceable calibration and data
1750-20-T, PRT with NIST traceable calibration and data
NVLAP - Accredited Calibrations available per request
   *Handle temperature outside this range will cause damage to the probe.

Optional Accessories

Model
Description
9001
Carrying Case for 1750-12
9002
Carrying Case for 1750-20

 

Overview

AM1760 series Secondary Standard PRT provides our customers an affordable SPRT alternative for precision temperature measurement and calibration in labs and fields. This SPRT features accuracy of ±0.006°C at 0.01°C , short term stability of ±0.002°C and very low drift rate of less than 19 mK after 500 hours. Two different lengths of SPRTs are available at 12-inch and 20-inch.   

The sensing element is designed to protect the platinum sensing wire from contamination at high temperatures, giving the device a high level of stability and repeatability in performance. A uniquely designed support structure and filling material provides excellent balance between the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe fully meets ITS-90 criteria for reference thermometers.
Features
·    Temperature range: -200 °C to 670 °C
·    Accuracy: ±0.006°C at 0.01°C
·    Long term drift: ±0.019°C
·    Short term stability: 0.002 °C
·    Temperature Coefficient 0.003925
·    W(Ga)>=1.11807
·    Inconeltm sheath
·    Customized dimensions available
Specifications
Temperature Range
-200°C to 670°C
Resistance at 0 °C
1760 - Nominal 100 Ω
1762 – Nominal 25 Ω
Temperature Coefficient
0.003925 Ω/ Ω/°C
Accuracy
±0.007°C at -196 °C
±0.006°C at 0.01 °C
±0.015°C at 420 °C
±0.025°C at 660 °C
Drift*
±0.004°C at 0 °C after 100 hours at 660 °C
Short Term Stability
±0.002°C
Thermal Shock
±0.002°C after 10 times thermal cycles from minimum to maximum temperatures
Self-heating
0.0015 °C at 1 mA current
Response Time
9 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current
0.5 mA or 1 mA
Sensor Length
42 mm
Sensor Location
5 mm from tip
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
Inconeltm
Dimension
1760/1762-12: 0.25 inch X 12 inch (6.35 mm X 305 mm)
1760/1762-20: 0.25inch X 20 inch (6.35 mm X 500 mm)
External Leads
Teflontm –insulated copper wire, 4 leads, 2.5 meters
Handle Dimension
15mm (OD) X 65 mm (L)
Handle Temperature Range**
-50°C to 180°C
Calibration Options
1760/1762-12-T, Secondary SPRT with NIST traceable calibration and data
1760/1762-20-T, Secondary SPRT with NIST traceable calibration and data
  *Long-term drift rate is for reference only. It could be affected by such facts as handling, application, and maintenance, etc.
  **Handle temperature outside this range will cause damage to the probe.
Optional Accessories
Model
Description
9001
Wooden Carrying Case for 1760/1762-12
9002
Wooden Carrying Case for 1760/1762-20

 
 
 

 

Overview

Standard Platinum Resistance Thermometers (SPRTs) are common used to interpolate temperature in the range from -189.3442°C to 660.323°C on the International Temperature Scale of 1990 (ITS-90).  They are widely used as standard or reference thermometers to calibrate other thermometers and to measure temperature precisely in primary and secondary laboratories. AM1850 and AM1860 SPRTs are the crown jewels of AccuMac temperature probes. It takes decades of our scientific expertise and original craftsmanship to create these world class products. They feature a very low drift rate. 

To improve the durability of the SPRT, Inconel 600 replaces quartz glass as sheath material of the thermometer. A special capsule is adopted to protect the platinum sensor wire from contamination introduced by metal sheath at high temperature. All parts used in the thermometer are completely cleaned and treated at high temperature before assembly. The gas mixture filled in the thermometer is well controlled to reduce oxidation effect as low as possible. Every SPRT is fully tested for stability after manufactured. This world class probe meets ITS-90 criteria of standard thermometer fully with a very competitive pricing.

AM1850 has a temperature range from -200°C to 500°C. AM1860 covers range from -200°C to 670°C. They are widely used as reference thermometer at drywell block calibrator and temperature bath.
Specifications
Temperature Range
1850: -200°C to 500°C
1860: -200°C to 670°C
Rtpw
Nominal 25 Ω or nominal 100 Ω
Resistance Ratio
W(Ga)>=1.11807
W(Hg)<=0.844235 span="">
Drift at 0.01°C*
1850      ΔR(0.01°C ) <0.002 c="" 100="" hours="" at="" 500="" span="">
                ΔR(0.01°C ) <0.008 c="" year="" span="">
1860      ΔR(0.01°C ) <0.003 c="" 100="" hours="" at="" 670="" span="">
                ΔR(0.01°C ) <0.01 c="" year="" span="">
Repeatability
±0.0015 °C
Thermal Shock
±0.0015 °C after 10 times thermal cycles from minimum to maximum temperatures
Self-heating
0.0015 °C at 1 mA current
Measurement Current
1 mA
Sensor Length
42 mm
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
InconelTM
Dimension
1850: 6.35 mm (OD) X 480 mm (L)
1860: 6.35 mm (OD) X 500 mm (L)
External Leads
Insulated copper wire, 4 leads, 2.5 meters
Termination
Gold-plated Spade
Handle Dimension
21mm (OD) X 80 mm (L)
Calibration
Not included
   *Long-term drift rate is for reference only. It could be affected by such facts as handling, application, and maintenance, etc.
Optional Accessories
Model
Description
9002
Complementary Wooden Carrying Case

 

Overview

Standard Platinum Resistance Thermometers (SPRTs) are used to interpolate temperature in the range from -189.3442°C to 660.323°C on the International Temperature Scale of 1990 (ITS-90).  They are widely used as standard or reference thermometers to calibrate other thermometers and to measure temperature precisely in primary and secondary laboratories. AM1950 and AM1960 SPRTs are the crown jewels of AccuMac temperature probes. It takes decades of our scientific expertise and original craftsmanship to create these world class products. They feature a very low drift rate. 

To reach the best performance in stability and repeatability, the sensing element and sensor support are specially designed. To protect the platinum sensing wire from contamination at high temperature, all parts used in the thermometer are extremely cleaned before assembly. The assembly process is well controlled to protect the sensor from contamination. The gas mixture filled in the thermometer makes the sensor wire oxidation effect as low as possible. Every SPRT is fully tested for stability after manufactured. This world class probe meets ITS-90 criteria of standard thermometer fully with a very competitive pricing.

AM1950 has a temperature range from -200°C to 500°C. AM1960 covers range from -200°C to 670°C.
Specifications
Temperature Range
1950: -200°C to 500°C
1960: -200°C to 670°C
Rtpw
Nominal 25 Ω
Resistance Ratio
W(Ga)>=1.11807
W(Hg)<=0.844235 span="">
Drift at 0.01°C*
1950      ΔR(0.01°C ) <0.002 c="" 100="" hours="" at="" 500="" span="">
                ΔR(0.01°C ) <0.004 c="" year="" span="">
1960      ΔR(0.01°C ) <0.003 c="" 100="" hours="" at="" 670="" span="">
                ΔR(0.01°C ) <0.005 c="" year="" span="">
Repeatability
±0.001 °C
Thermal Shock
±0.001 °C after 10 times thermal cycles from minimum to maximum temperatures
Self-heating
0.0015 °C at 1 mA current
Measurement Current
1 mA
Sensor Length
42 mm
Insulation Resistance
>1000 MΩ at room temperature
Sheath Material
Fused-Quartz
Dimension
1950: 7 mm (OD) X 480 mm (L)
1960: 7 mm (OD) X 500 mm (L)
External Leads
Insulated copper wire, 4 leads, 2.5 meters
Termination
Gold-plated Spade
Handle Dimension
21mm (OD) X 80 mm (L)
Calibration
Not included
    *Long-term drift rate is for reference only. It could be affected by such facts as handling, application, and maintenance, etc.
Optional Accessories

 

Model
Description
9002
Complementary Wooden Carrying Case

 

Overview

AM8010 is a handheld digital thermometer with high accuracy, fast readings and great stability. This readout is perfect for field applications as well as lab measurement. Though small in size, AM8010 is powerful when it comes to accuracy, which can be as high as 0.01 °C at 0 °C. A USB interface allows user to log and display real time data on a PC.

AM8010 digital thermometer allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response various PRTs. All probe constants and coefficients can be keyed in through front panel.

This portable readout is a powerful device with relative small price.

Features

·       High accuracy: ±0.03 °C at 0 °C 

·       High resolution: 0.01 °C over the full range

·       Temperature range: -200 °C to 850 °C

·       Work with PRTs with α=0.00385 and  α=0.003925

·       ITS-90, CVD, IEC-751

·       2.7 inch OLED display

·       Full-size Touchpad for function control

·       Temperature can be displayed in °C, °F or ohm.

·       Flexible interface with user key-in coefficients

·       USB interface with PC for real time data saving and displaying on PC

·       Dual power supply with batteries or external power adaptor/computer USB interface
Specifications
 
Temperature Range
-200°C to 850°C, depending on PRT used
Accuracy (meter only)
±0.04°C @ -200°C
±0.03°C @ 0°C
±0.04°C @ 232°C
±0.05°C @ 420°C
±0.06°C @ 660°C
±0.07°C @ 850°C
Resolution
0.01°C (0.001 Ω) over full range
Stability
±0.01°C 
Probe
100 Ω RTD, PRT or SPRT
Characterizations
ITS-90 coefficients, Callender Van Dusen coefficients, IEC-751 (DIN 385)
Sample Interval
1 second
Display
2.7 inch OLED
Display Units
°C, °F, Ω
Excitation Current
1 mA, reversing
Operation Range
15 °C to 35 °C
Thermometer Input Connectors
5-pin plug
Power Requirements
100-240 V
Dimension
141mm (L) X 25 mm (H) X 89 mm (W)
Weight
0.2 kg (0.5 lbs)
 
Optional Accessories
 
Model
Description
1610-12/9/6
Precision Industrial PRT, -60°C to 160°C
1620-12/9/6
Precision industrial PRT, -60°C to 300°C
1640-12
Precision industrial PRT, -200°C to420°C
1660-12
Precision industrial PRT, -200°C to 670°C
1730-12
Secondary Reference PRT, -200°C to 420°C
1750-12/20
Secondary Reference PRT, -200°C to 670°C
1850-100
Metal-sheath SPRT, -200°C to 500°C
1860-100
Metal-sheath SPRT, -200°C to 670°C

 

 

Overview

AM8040 Precision Thermometer provides the best values with high standard performance. It features high accuracy, fast readings and great stability. It operates with a wide range of Platinum Resistance Thermometers (PRTs). All of the readings can be stored in a USB flash disk or transferred to PC through an USB cable or a wireless module.
AM8040 Precision Thermometer allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response to various PRTs. Users can also choose to key in calibration data of each PRT to ensure the best accuracy.
AM8040 is the solution for precision temperature measurement and calibration at a very attractive price.
Features
·    High accuracy: up to ±0.008 °C at 0 °C
·    High resolution: 0.001 °C over the full range
·    Temperature range: -200 °C to 850 °C
·    ITS-90, CVD, IEC-751 conversion methods or key in coefficients of PRTs
·    2.7 inch OLED display
·    Full-size Touchpad for function control
·    Data storage into USB flash disk
·    Data transfer to PC using an USB cable
·    Wireless data transfer to PC with an optional wireless module
Specifications
 
Temperature Range
-200°C to 850°C, depending on PRT used
Accuracy (meter only)
±0.01°C @ -200°C
±0.008°C @ 0°C
±0.009°C @ 232°C
±0.01°C @ 420°C
±0.015°C @ 660°C
±0.025°C @ 850°C
Resolution
0.001°C (0.0001 Ω) over full range
Probe
Nominal Rtpw: 25 Ω or 100 Ω RTD, PRT or SPRT
Characterizations
ITS-90 coefficients, Callender Van Dusen coefficients, IEC-751 (DIN 385)
Sample Interval
1 second
Display
2.7 inch OLED
Display Units
°C, °F, Ω
Excitation Current
1 mA, reversing
Operation Range
15 °C to 35 °C
Thermometer Input Connectors
Spade plug or bare wire
Power Requirements
100-220V
Dimension
180 mm (W) X 65 mm (H) X 200 mm (D)
Weight
0.3 kg (0.7 lbs)
 
Optional Accessories
 
Model
Description
8000-WLM
Wireless module for AM-8040 and AM-8060 precision thermometer
1610-12/9/6
Precision Industrial PRT, -60°C to 160°C
1620-12/9/6
Precision industrial PRT, -60°C to 300°C
1640-12
Precision industrial PRT, -200°C to420°C
1660-12
Precision industrial PRT, -200°C to 670°C
1730-12
Secondary Reference PRT, -200°C to 420°C
1750-12/20
Secondary Reference PRT, -200°C to 670°C
1850
Metal-sheath SPRT, -200°C to 500°C
1860
Metal-sheath SPRT, -200°C to 670°C
1950
Quartz-sheath SPRT, -200°C to 500 °C
1960
Quartz-sheath SPRT, -200°C to 670 °C

 
 

 

Overview
AM8060 Precision Thermometer provides high accuracy, fast readings and great stability. It comes with dual channel measurement of temperature with Platinum Resistance Thermometers (PRTs). The temperature of each input and their temperature difference are displayed simultaneously. All of the readings can be stored in a USB flash disk or transferred to PC through a wireless module or an USB cable.
AM8060 Precision Thermometer allows users to choose ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods to response to various PRTs. Users can also choose to key in calibration data of each PRT to ensure the best accuracy.
This dual-channel readout is a perfect choice for precision temperature measurement and calibration. It’s also a top choice as temperature reference for Drywell Calibrators and Temperature Bath.
Features
·    High accuracy: up to ±0.008 °C at 0 °C
·    High resolution: 0.001 °C over the full range
·    Temperature range: -200 °C to 850 °C
·    Two inputs for reading two different sensors simultaneously
·    Differential temperature measurement
·    ITS-90, CVD, IEC-751
·    2.7 inch OLED display
·    Full-size Touchpad for function control
·    User key-in coefficients to ensure the best accuracy
·    Data storage into USB flash disk
·    Data transfer to PC using an USB cable
·    Wireless data transfer to PC with an optional wireless module
 
Specifications
 
Temperature Range
-200°C to 850°C, depending on PRT used
Accuracy (meter only)
±0.01°C @ -200°C
±0.008°C @ 0°C
±0.009°C @ 232°C
±0.01°C @ 420°C
±0.015°C @ 660°C
±0.025°C @ 850°C
Resolution
0.001°C (0.0001 Ω) over full range
Probe
Nominal Rtpw: 25 Ω or 100 Ω RTD, PRT or SPRT
Characterizations
ITS-90 coefficients, Callender Van Dusen coefficients, IEC-751 (DIN 385)
Sample Interval
1 second
Display
2.7 inch OLED
Display Units
°C, °F, Ω
Excitation Current
1 mA, reversing
Operation Range
15 °C to 35 °C
Thermometer Input Connectors
Spade plug or bare wire
Power Requirements
100-220V
Dimension
180 mm (W) X 65 mm (H) X 200 mm (D)
Weight
0.3 kg (0.7 lbs)
 
Optional Accessories
 
Model
Description
8000-WLM
Wireless module for AM-8040 and AM-8060 precision thermometer
1610-12/9/6
Precision Industrial PRT, -60°C to 160°C
1620-12/9/6
Precision industrial PRT, -60°C to 300°C
1640-12
Precision industrial PRT, -200°C to420°C
1660-12
Precision industrial PRT, -200°C to 670°C
1730-12
Secondary Reference PRT, -200°C to 420°C
1750-12/20
Secondary Reference PRT, -200°C to 670°C
1850
Metal-sheath SPRT, -200°C to 500°C
1860
Metal-sheath SPRT, -200°C to 670°C
1950
Quartz-sheath SPRT, -200°C to 500 °C
1960
Quartz-sheath SPRT, -200°C to 670 °C